This page reflects data collected from my testing of 250 watt MH lamps and ballasts. The colors of the lamps over my tank can be seen below. Every effort has been made to represent the colors as they truly look over my tank. The information under the ballast section represents the PAR output of the lamp being driven as well as the ballast power consumption. Note the data under the ballast is not the power going to the lamp, rather what the ballast is drawing from the wall outlet.
To see the whole thread this information is taken from please visit Reef Central.
These tests were conducted to measure Photsynthetically Available Radiation (PAR) output from 250 watt Metal Halide SE lamps. PAR is the available light between 400-700nm (nanometers). This spectrum is the light spectrum that we, as humans, can see. It is also the area in which photosynthesis occurs in plants. There are considerable discussions to whether the whole PAR spectrum applies to corals or whether just a few narrow bands. So far there is no definitive proof one way or the other. So PAR is still the best measure we presently have of judging how intense the lamps output is in relation to coral usage.
How these tests were conducted.
The lamps tested were burned in at least 120-150 hours. All lamps with the exception of the Ushio, AB and Blueline Super White, were new. The Ushio, AB and Blueline Superwhite had roughly 6 months use on them (aprox 1600hrs). A 2’ x 2’ square box was constructed, the inside painted flat black. The mogul socket was mounted horizontally aprox 5” from the ceiling of the box. The quantum sensor was place 8” below the center of the arc tube. A voltage regulator was used on power from the wall electrical socket. A watt meter was plugged into the voltage regulator and the ballast plugged into the watt meter. All electrical readings under the ballast section are measurements of the power being drawn by the ballast not the power going to the lamp.
All lamps, before testing, were fired and left to burn for at least 20 minutes before any measurement were performed. After 20 minutes, the sensor was turned on and time was given for a stable reading to be displayed from the meter. Sometime between 2-5 minutes the reading on the meter would stabilize for at least 30 seconds with no movement, at that time readings were recorded.
Equipment used
Apogee Instruments QMSS-ELEC Quantum meter with sensor. Calibrated for electric lamps.
Apogee Instruments leveling plate for the senor
APC LINE-R 600, Voltage regulator/Power Conditioner.
Electronic Educational Devices Watts Up?, Power Analyzer/Watt Meter.
Nikon 995 digital camera used with tripod for pictures.
Actual power to lamp.
Here are some measurements that were taken to see how the ballast actually drive the lamp. On the Radium lamp the Standard PFO ballast would not drive start the lamp, so no information is given.
Measurements were taken using a BK 5390 Multimeter. Measurements for current are TRMS. Both AC and AC+DC were taken as the electronic ballasts seem to use the DC signwave as well. All measurements were taken on the wire between the ballast and lamp. The lamps were first ignited by the ballast then let to burn for 20 minutes, at that time measurements were taken. The first line for the lamp in bold are the manufactures specifications of the lamp, what follows are the reading from running the lamp on different ballasts.
LAMP BALLAST AC AMP AC+DC AMP Volts kHz Line watts Line voltsRadium SPEC 2.80 2.80 95-100Radium HQI 2.63 2.63 113.50 59.98 Hz 308 117Radium ARO 3.20 4.79 112.37 76.80 249 117Radium eballast 2.21 1.95 110.65 80.73 242 121Radium IceCap 3.20 4.58 109.60 70.47 248 119Radium CV 2.29 2.01 109.63 67.52 264 119Radium ReefFanatic 2.28 2.80 131.90 42.03 246 119Radium EVC 2.37 2.88 115.80 44.68 247 119Ushio SPEC 3.00 3.00 100.00Ushio ARO 2.94 4.64 125.43 77.95 249 119Ushio Standard 2.11 2.11 129.34 59.98Hz 273 118Ushio HQI 2.43 2.43 133.41 59.98Hz 339 118Ushio eballast 1.80 1.59 123.04 86.68 243 119Ushio IceCap 2.87 4.40 127.78 73.43 254 119Ushio CV 1.84 1.62 125.39 72.84 254 121Ushio ReefFantic 2.62 3.20 116 44.06 246 119Ushio EVC 2.10 2.42 132.20 41.98 246 120
Lamp heat due to ballasts Ballasts contribute to the amount of heat produced by the lamp. Temperature measurements were taken at the same distance from the lamp as the sensor, 8". The ballast was turned on with a fan above the lamp pulling heat out. After 35 minutes the temperature at 8" from the lamp was taken then the fan was turned off. After 10 minutes more (for a total of 45), temperature was taken again and recorded.
Ballast Lamp 0 Min 35 Min 45 Min/No FanPFO Standard Ushio 70.0F 83.2F 90.1FPFO HQI Ushio 70.3F 87.5F 97.2Feballast Ushio 70.5F 81.4F 89.5FIcecap Ushio 70.1F 78.6F 85.2FCoralVue Ushio 70.3F 82.1F 90.6FARO Ushio 70.2F 79.6F 88.3F
Apogee senor accuracy There were numerous questions as to the accuracy of the apogee sensor used in the test. To answer questions as to the margin of error that this sensor produced, I contacted apogee and discussed this with them. They agreed to send to me two LiCor sensor that they use for in house for testing. The sensors were first calibrated by them and then sent to me. Measurements were then taken using the two LiCor sensor then averaged to produce a value. The reading from the Apogee was then compared to that obtained by the LiCor sensors. The table below shows the margin of error the apogee was off compared to the LiCor. Also shown is a differential factor. If this factor is applied to the apogee reading, it will correct for any deficiencies of the sensor. As all lamps have a slightly different spectral curve it if different for each lamp.
LAMP Adj factor Error %AB10K 1.042700 4.27XM10K 1.000102 0.01XM20K 1.054623 5.46Radium 1.020256 2.03CV10K 1.014444 1.45Ushio10K 1.022647 2.26PFO13K 1.066219 6.62Iwasaki 1.004403 4.40BLSW 1.035931 3.59SUN10K 1.041306 4.13CV15k 1.062583 6.26CV20K 1.031709 3.17BL10K 1.020969 2.10HM14K 1.041438 4.14AC14K 1.027771 2.77SUNBRST 1.025221 2.52CV12K 1.076923 7.69SUN14K 1.026404 2.63
Picture on the left is with actinics off. Picture on the right is with (2) 140 watt URI VHO actinics on.
AB13K: Aqualine Buske 13000K
AC14K: AquaConnect 14000K
BL10K: Blueline 10K 250 watt MH
BLSW: Blueline Super White
CV10K: CoralVue 10000K
CV12K:
CV15K: CoralVue 15000K
CV20K: CoralVue 20000K
EVC10K: EVC 10000K
HM14K: Hamilton 14K
Iwasaki: Iwasaki 6500K
PFO 13K: PFO 13000K
Radium:
SBURST12K:
SUN10K: Sun Aquatics 10000K
SUN14K:
SUN20K:
Ushio: Ushio 10000K MH
XM10K: XM 10000K
XM20K: XM 20000K
ARO (Hellolights) Electronic Ballast Lamp PAR Watts MaxWatts Amps MaxAmp Iwasaki 605 250 253 2.11 2.19 XM10K 526 250 251 2.16 2.37 BLSW 465 250 254 2.16 2.2 EVC10K 463 249 256 2.16 2.19 SUN10K 461 248 256 2.14 2.23 AB13K 434 252 254 2.15 2.51 Ushio 408 251 269 2.14 2.61 AC14K 391 253 258 2.23 2.33 CV10K 360 249 251 2.11 2.15 HM14K 338 249 253 2.17 2.63 Radium 327 249 252 2.18 2.23 AMX14K 310 252 277 2.19 2.49 SBURST12K 302 250 270 2.18 2.5 CV20K 286 249 265 2.16 2.55 XM20K 270 250 253 2.16 2.41 SUN14K 259 249 255 2.15 2.37 CV12K 258 250 273 2.17 2.48 BL10K 253 246 250 2.14 2.19 CV15K 243 250 252 2.16 2.22 SUN20K 227 246 278 2.17 2.53 PFO 13K 206 251 252 2.16 2.19 XM15K 171 252 256 2.2 2.27 CoralVue Electronic Ballast Lamp PAR Watts MaxWatts Amps MaxAmp Iwasaki 569 247 266 2.0 2.36 XM10K 541 257 270 2.12 2.5 BLSW 480 252 270 2.02 2.2 CV10K 430 262 265 2.1 2.13 AB13K 368 224 268 1.8 2.39 HM14K 363 258 268 2.09 2.49 Ushio 363 255 265 2.08 2.38 Radium 337 260 269 2.13 2.89 CV20K 316 260 265 2.09 2.22 CV15K 311 260 265 2.1 2.16 BL10K 265 256 261 2.09 2.12 XM20K 257 248 269 2.01 2.19 PFO 13K 203 244 268 1.97 2.17 Blueline E-Ballast Electronic Ballast Lamp PAR Watts MaxWatts Amps MaxAmp Iwasaki 558 244 247 1.99 2.14 XM10K 521 243 244 2.0 2.03 BLSW 474 246 250 1.99 2.11 SUN10K 468 244 245 1.99 2.0 EVC10K 468 245 249 1.99 2.05 Ushio 430 245 247 2.0 2.03 AB13K 428 246 249 1.99 2.09 AC14K 390 246 247 2.0 2.03 Radium 343 243 244 1.98 2.0 CV10K 341 242 243 1.95 1.96 CV20K 340 242 244 1.93 2.0 HM14K 323 242 243 1.95 2.05 AMX14K 318 247 248 2.0 2.18 SUN14K 266 240 241 1.93 1.95 BL10K 261 240 242 1.93 2.71 CV12K 243 242 268 1.98 2.52 CV15K 238 242 243 1.95 2.21 SUN20K 234 240 240 1.92 2.64 XM20K 228 244 250 1.99 2.12 XM15K 194 248 249 2.0 2.24 PFO 13K 178 244 245 1.97 1.99 EVC Ballast Lamp PAR Watts MaxWatts Amps MaxAmp XM10K 559 246 249 2.03 2.8 Iwasaki 517 247 250 2.03 2.87 AC14K 438 250 254 2.03 2.1 SUN10K 425 247 248 2.01 3.29 BLSW 423 247 249 2.0 3.2 EVC10K 412 246 248 2.01 2.08 Ushio 394 247 248 2.02 3.65 HM14K 350 246 250 2.01 2.06 AMX14K 316 246 250 2.03 2.51 Radium 294 247 248 2.03 2.59 SBURST12K 291 246 251 2.01 3.66 BL10K 290 247 248 1.98 2.37 SUN14K 261 246 248 2.0 3.33 CV12K 257 246 294 1.97 2.02 XM20K 254 246 247 2.0 2.59 SUN20K 241 247 248 2.01 2.14 XM15K 211 252 256 2.07 2.12 PFO 13K 184 246 248 2.0 2.4 IceCap Electronic Ballast Lamp PAR Watts MaxWatts Amps MaxAmp Iwasaki 651 252 275 2.17 2.45 XM10K 530 252 254 2.2 2.82 BLSW 494 252 254 2.15 2.83 SUN10K 494 252 255 2.14 3.86 EVC10K 492 252 254 2.15 2.96 AB13K 422 254 257 2.17 2.3 Ushio 414 252 258 2.19 3.41 AC14K 406 252 264 2.17 2.32 CV10K 387 250 251 2.17 2.46 HM14K 352 251 252 2.17 2.29 Radium 330 252 275 2.19 3.56 AMX14K 308 252 275 2.19 2.5 CV20K 307 251 253 2.2 2.25 SBURST12K 304 253 284 2.17 2.61 XM20K 270 252 301 2.17 2.81 BL10K 263 248 250 2.18 3.68 CV12K 259 251 253 2.17 3.32 SUN14K 253 251 308 2.18 2.79 CV15K 242 251 252 2.2 3.85 PFO 13K 227 251 268 2.18 2.86 SUN20K 224 247 249 2.2 3.0 XM15K 187 252 254 2.17 2.83 PFO HQI Lamp PAR Watts MaxWatts Amps MaxAmp Iwasaki 950 355 384 3.02 4.79 XM10K 835 340 341 2.93 4.07 BLSW 702 349 359 3.0 5.72 EVC10K 700 345 350 2.99 3.87 SUN10K 699 342 346 2.95 3.36 AB13K 659 341 349 2.96 4.55 Ushio 617 349 360 3.0 7.42 CV10K 457 333 335 2.87 3.25 AC14K 453 311 313 2.85 4.74 HM14K 420 317 361 2.79 6.86 Radium 395 311 315 2.75 3.28 SBURST12K 378 311 698 2.79 14.27 AMX14K 366 322 400 2.89 11.34 CV20K 355 321 330 2.79 5.18 CV15K 336 317 322 2.76 4.55 CV12K 328 310 314 2.73 4.45 XM15K 318 312 847 2.79 16.33 SUN14K 314 327 490 2.92 8.69 XM20K 314 327 337 2.85 3.94 PFO 13K 308 311 418 2.76 8.08 BL10K 292 310 385 2.83 10.03 SUN20K 232 292 393 2.81 10.65 PFO Standard Lamp PAR Watts MaxWatts Amps MaxAmp Iwasaki 691 286 331 2.53 6.86 XM10K 600 268 269 2.47 3.39 AB13K 566 301 303 2.64 3.81 BLSW 514 273 274 2.49 5.47 EVC10K 512 271 278 2.5 3.12 SUN10K 510 270 277 2.51 2.69 Ushio 485 284 285 2.53 4.57 CV10K 324 231 233 2.32 4.03 SBURST12K 309 269 269 2.51 6.01 Radium 283 231 232 2.38 6.81 AMX14K 276 247 253 2.49 5.05 CV20K 275 226 261 2.3 7.93 XM15K 264 265 267 2.55 7.42 PFO 13K 248 257 258 2.5 6.8 CV15K 242 227 239 2.35 4.14 XM20K 242 285 285 2.57 3.75 SUN14K 228 224 228 2.32 4.08 AC14K 228 212 274 2.33 8.29 HM14K 214 219 220 2.3 7.12 CV12K 190 230 230 2.38 3.54 SUN20K 148 198 199 2.25 6.11 Reef Fanatic Lamp PAR Watts MaxWatts Amps MaxAmp XM10K 571 247 248 2.03 2.77 Iwasaki 523 247 248 2.03 3.3 BLSW 454 246 247 2.0 3.75 AC14K 441 247 249 2.03 2.62 SUN10K 420 246 249 1.98 3.68 EVC10K 417 247 248 2.01 3.44 Ushio 383 246 248 2.04 2.67 HM14K 350 247 248 2.03 2.6 AMX14K 315 247 248 2.04 2.64 BL10K 294 246 247 1.94 2.7 SBURST12K 283 247 250 2.01 2.21 SUN14K 257 246 247 2.01 2.15 CV12K 252 246 248 2.0 2.92 XM20K 246 246 334 2.03 3.31 SUN20K 239 246 247 2.0 2.02 XM15K 209 251 253 2.07 2.09 PFO 13K 185 246 248 2.0 3.35